PAA-6069 交流電流控制顯示錶
簡介
- 交流電流 : 0 to 10.00 A, 40 to 400 Hz.
電流輸入可外接 CT . CT100A/5A 或 CT1000A/5A
上限或下限範圍設定及警報設定功能
上限或下限設定及警報設定繼電器輸出
工作電源:AC90 ~ 264V (50/60HZ)
RS-232 / USB 連接介面(軟體選購)
Size: 96x48x107mm
FEATURES
Professional ACA meter with standard DIN case ( 96 x 48 mm ) and Control/Alarm function.
Microprocessor circuit ensures high accuracy and provide special functions and features.
Large red LED display, high brightness and easy to read.
Input signal ( without CT ) : ACA : 0.05 to 10.00 ACA, 40 to 400 Hz.
True rms for ACA measurement.
ACA input can cooperate the external CT ( Current transformer ) to expend the measurement range. The CT range can be adjusted with default.
Control setting, Hi/Lo alarm setting.
Control relay output, alarm relay output.
Control Relay will make action when the reading value reach to control value.
Alarm Relay will make action when the reading value reach to high/low alarm value.
Hysteresis value setting for control and alarm function.
Power : 90 ACV to 264 ACV, 50/60 Hz.
RS232/USB computer interface.
Option data acquisition software.
一般規格
顯示 (Display)
- 4 digits red LED, digit size
- 14 mm ( 0.55 inch ) digit height .
- 5 indicators .
PV ( process value ) indicator
SV ( set value ) indicator
Control out indicator
Alarm out indicator
A ( ACA ) indicator
電路 (Circuit)
- Custom chip of microprocessor LSI circuit.
交流電流測量 (ACA measurement )
- 0.05 ACA to 10.00 ACA.
- * True rms value
取樣時間 (Sampling Time)
- Approx. 0.8 second.
繼電器輸出 (Relay Output)
- Number : 2 relays
- Function : Relay 1 : control relay. ; Relay 2 : High/Low alarm relay.
- Max load : 0.5 ACA/250 ACV ; 0.5 DCA/24 DCV *Do not apply the relay contact load current > 0.5 A, other wise the relay may be damaged permanently without warranty.
資料輸出 (Data Output)
- RS232 / USB PC Computer interface.
- * Connect the optional RS232 cable , UPCB - 02 will get the RS232 plug.
- * Connect the optional USB cable, USB - 01 will get the USB plug.
設定功能 (Setting Function)
1st layer setting procedures
- CtLo ( Control low limit )
- CtHi ( Control high limit )
- ALLo ( Alarm low limit )
- ALHi ( Alarm high limit ).
Second layer setting procedures
- CtSt ( CT rate setting )
- CtHy ( Control hysteresis value setting )
- ALHy ( Alarm hysteresis value setting )
過載輸入 (Over input)
- " - - - - " mark indication.
歸零調整 (Zero Adjustment)
- Automatic adjustment.
操作溫度 (Operating Temperature)
- 0 to 50 ℃.
操作溼度 (Operating Humidity)
- Less than 80% R.H.
電源供應 (Power Supply)
- 90 to 260 ACV, 50/60 Hz.
重量 (Weight)
- 261 g/ 0.57 LB.
電源損耗 (Power Consumption) * Under no load
- Approx. 3.3 VA/AC 110V.
- Approx. 4.9 VA/AC 220V.
體積大小 (Dimension)
- DIN size : 96 x 48 mm.
- Panel cut size : 92 x 46 mm.
- Depth : 110 mm.
附件 (Accessories Included)
- Instruction manual........................1 PC
- Case holder with screw................. 2 PCs
選購附件 (Optional Accessories)
- Data Acquisition software, SW-U801-WIN.
- RS232 cable, UPCB-02.
- USB cable, USB-01.
- Real time SD card datalogger DL-9602SD
- GSM controller, GSM-889.I
- Interface cable ( cable between meter to GSM-889 ), GMCB-89.
電器規格
沒有 CT直接輸入 (Without CT ( direct input ))
Range : 0.05 ACA to 10.00 ACA
Resolution : 0.01 ACA
Accuracy : ± ( 0.5 % + 5d ) reading
Remark :
- * T16, T15 ACA input : 0.05 ACA to 10.00 ACA.
- * Accuracy is test under input signal is sine wave, 50/60 Hz.
- * ACA frequency response is from 40 to 400 Hz
- * ACA measurement is True RMS value.
- * Accuracy value is specified within 23℃ ± 5℃
含 CT ( With CT ( Current transformer ))
Range : 1 ACA to 2000 ACA
Resolution : 1 ACA
Accuracy : ± ( 0.5 % + 5d ) reading
Remark :
- * Measuring Signal come from the rear terminals .
- * T16, T15 ACA input : 0.05 ACA to 10 ACA. CT ( current transformer ) adjust value : x 1 to x 200.
- * Accuracy is test under input signal is sine wave, 50/60 Hz.
- * Accuracy is specified for the meter only, not include the accuracy of CT ( current transformer ).
|