• 公所簡介
  • 最新消息
  • 教育訓練
  • 會員專區
  • 產品搜尋
  • 共同天線
  • 招標訊息
  • 意見交流
  • 活動剪影
  • 網網相連

會員登入

忘記密碼
HV-40高壓衰減棒 HOME » 上偉科技企業有限公司 » 電子型錄

 
1.
照片-1


上一個商品
 

 

HV-40 高壓衰減棒

 

HV-40 高壓衰減棒

 

特色

  • 衰減比例 : 1000:1

  • 測量範圍 :

                                DCV(直流)1KV ~ 40KV

                                ACV(交流)1KV ~ 28KV.(50/60Hz)

  • 精確度 : DCV ±1% . ACV ±5%

  • 輸入阻抗約 1000M

規格

衰減比 (Attenuate Ratio)

1 : 1000.

輸入阻抗 (Input Impedance)

Approx. 1000 M ohm.

輸出 (Output)

Around 1.1 M ohm. The input impedance of external voltmeter

阻抗 (Impedance)

should be 10 mega ohm.

安全性 (Safety)

Meet CAT II 40000 V

最大工作電壓 (Max. Working Voltage)

DCV : DC 40 KV
ACV : Peak AC 40 KV or 28 KV rms ( depend which values is larger ).

精確度 (Accuracy)

DCV : 1 KV to 20 KV - ± 1 %. ; 20 KV to 40 KV - ± 1.5 %.
ACV : 1 to 28 KV rms, 50/60 Hz - ± 5 %.

溫度係數 (Temp Coefficient)

Less than 200 ppm/蚓.

操作溫度 (Operating Temp.)

0 to 50 ℃ ( 32 to 122 ℉ ).

操作溼度 (Operating Humidity)

Less than 80 % R.H.

電纜長度 (Cable Length)

1 meter.

操作 (OPERATION)

Connect the plugs to the volts ( Hi ) & com ( Lo ) input terminals of your voltmeter ( or Multimeter ). Select the desired range of voltmeter ( Attention : Do not use auto ranging ).
Whenever possible, turn the high voltage source off before making any connections. Connect the HV probe common lead ( alligator clip ) to a good earth ground or reliable chassis ground.

安全預防措施和警告 (SAFETY PRECAUTION & WARNING !!!)

* This high voltage probe must be used by the person who are trained only. Do not work alone when working with high voltage circuits & environment.
* For your own safety, inspect the probes for cracks & frayed or broken leads before each use. If any defects are noted, do not use the probes.
* Hands, shoes, floor & work bench must be dry. Avoid making measurements under humid, damp or other environmental conditions that might affect the safety of measurement situation.
* The ground connection must always be made before the probe tip comes into contact with the high voltage & must not be removed until after the probe tip has been removed from high voltage source.
* Do not attempt to take measurement from sources where the chassis or return lead is not ground.
* If possible, always turn the high voltage source off before connecting or disconnecting the probe.
* Before turning the high voltage on, make sure that no part of your body is in contact with the device under test.
* The probe body should be kept clean & free of any conductive contamination. Clean only the exterior probe body & cables. Use a soft cotton cloth lightly moistened with a mild solution of detergent & water. Do not allow any portion of the probe to be submerged at any time.


接地電阻計及高壓衰減棒

ET-3000 接地電阻計

ET-3000 接地電阻計

HV-40 高壓衰減棒

HV-40 高壓衰減棒

ET-3000 接地電阻計資料說明

HV-40 高壓衰減棒資料說明

ET-3000 接地電阻計操作手冊

 

回上偉通信資訊網服務網首頁

維修服務力求精確快速、工程安裝務必確實穩固、產品銷售首重公道合理、任何需求歡迎上班時來電 02-22267567(代表號) 有專人為您接聽服務

電信網通 監視影音 廣播音響 安全防盜 門禁對講 資訊網絡 電子事務 精密儀器 機電建材 綜合商品