YK-2005AM 記憶式風速/風量/溫度計
特色
-
記錄 16000 筆資料 , 含時間記錄 (年月日時分秒)
-
風速範圍 :
0.5 ~ 40.0 公尺/秒 ±2%
CMM : 0 ~ 999900 m3/min
CFM : 0 ~ 999900 ft3/min.
-
風速溫度範圍 : 0°C ~ 50.0°C ±0.8°C.
-
溫度 :
Type K : -50.0 ~1300.0°C. ±0.2%
Type J : -100.0 ~1100.0°C. ±0.2%
-
可記錄最大值,最小值及讀值鎖定功能..
-
RS-232 / USB 輸出介面.(軟體選購)
-
Size : 203 x 76 x 38mm.
FEATURES
Air velocity : m/S, Ft/min, Km/h, Knots, Mile/h,
Air flow : CMM ( m^3/min. ) and CFM ( ft^3/min. ).
Air temperature ( ℃, ℉ )
Type K/ Type J thermocouple thermometer.
Real time data logger, build in clock ( hour-min.-sec., year-month-date ).
Auto data record, 16,000 Data logger no.
Wide sampling time adjustment range from two seconds to 8 hours 59 minutes 59 seconds.
RS232 computer interface.
Can default auto power off or manual power off.
Can default the air velocity, air flow, Temp. unit.
Air flow measurement can set the area dimension.
Multi function with easy operation
Low-friction ball vane wheels make sure high accuracy in high & low velocities.
Metal vane, high reliability.
Large LCD with multiple display.
Data hold, record max. and min. reading.
Microcomputer circuit provides special function & offer high accuracy.
Air Temp. used thermistor sensor, fast response time.
Power by UM3 ( 1.5 V ) x 4 batteries or DC 9V adapter.
RS232 PC serial interface.
Separate probe, easy for operation of different measurement environment.
Wide applications: use this anemometer to check air conditioning & heating systems, measure air velocities, wind temperature...etc.
一般規格
電路 (Circuit)
- Exclusive one-chip of microcomputer LSI circuit.
顯示 (Display)
- LCD size : 58 mm x 34 mm.
測量 (Measurement)
- Air velocity:
- m/s ( meters per second )
- km/h ( kilometers per hour )
- Knot ( nautical miles per hour )
- ft/min ( feet per minute )
- mile/h ( miles per hour )
- Air flow:
- CMM ( m^3/min. )
- CFM ( ft^3/min. ).
- Air Temperature : ℃ or ℉.
- Type K/ Type J thermometer. ℃, ℉
資料集錄器取樣時間 (Sampling Time of Data Logger)
- 2 sec to 8 hour 59 min. 59 sec. @ Auto datalogger
感應器結構 (Sensor Structure)
- Air velocity & Air flow : Conventional twisted van arm and low friction ball bearing design. vane use metal material.
- Temperature : Thermistor.
- Type K/ Type J thermometer. Thermocouple
溫度補償 (Temperature Compensation)
- Automatic temp. compensation for the Type K/J thermometer.
資料鎖定 (Data hold)
- Freeze the display reading.
記憶回叫 (Memory Recall)
- Record maximum & minimum reading value with recall.
顯示的取樣時間 (Sampling Time of display)
- Approx. 1 sec
關機 (Power off)
- Auto shut off saves battery life. or manual off by push button.
資料輸出 (Data Output)
- RS 232 PC serial interface.
操作溫度 (Operating Temp. )
- 0℃ to 50℃( 32℉to 122℉).
操作溼度 (Operating Humidity)
- Less than 80% R.H.
電源供應 (Power Supply)
- Alkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 4 PCs.
- DC 9V adapter input. * AC/DC power adapter is optional.
電源損耗 (Power Consumption)
- Approx. DC 21.5 mA @ Main instrument.
- DC 27.5 mA. @ Main instrument. + Anemometer probe.
重量 (Weight)
- 515 g/ 1.13 LB. @ Battery is included.
尺寸 (Size)
- Main instrument : 8203 x 76 x 38 mm
- Anemometer sensor head : Round, 72 mm Dia.
附件 (Standard Accessory)
- Instruction manual.................... 1 PC
- Anemometer probe........................ 1 PC.
- Carrying Case.................. 1 PC.
選購附件 (Optional & accessories Temp. Probe)
- Type K thermocouple probe.
- AC to DC 9V adapter
- RS232 cable/UPCB-02, USB cable/USB-01
- Data Acquisition software, SW-U801-WIN.
- Data Logger software, SW-DL2005.
電器規格 ELECTRICAL SPECIFICATIONS (23 ±5℃)
風速 (Air velocity)
Measurement |
Range |
Resolution |
Accuracy |
m/S |
0.4 - 30.0 m/s |
0.1 m/s |
± (2% + 0.2 m/sec) |
Km/h |
1.4 - 126.0 km/h |
0.1 km/h |
± (2% + 0.8 km/h) |
Knot |
0.8 - 68.0 knots |
0.1 knots |
± (2% + 0.4 knots) |
Ft/min |
79 - 6890 ft/min |
1 ft/min |
± (2% + 40 ft/min) |
Mile/h |
0.9 - 78.3 mph |
0.1 mile/h |
± (2% + 0.4 mile/h) |
Remark :
ft/min : feet per minute ; MPH : miles per hour ; m/s : meters per second ; knots : nautical miles per hour ; km/h : kilometers per hour ; Ft-cd : feet candle
風量 (Air flow)
Measurement |
Range |
Resolution |
Area |
CMM ( m^3/min. ) |
0-999,900 m^3/min. |
0.001-100 m^3/min. |
0.001-9,999 m^3/min. |
CFM ( ft^3/min. ). |
0-999,900 ft^3/min. |
0.001-100 ft^3/min. |
0.001-9,999 ft^3/min. |
溫度 (Air Temperature)
Measurement |
Range |
Resolution |
Accureacy |
Temperature |
0 ℃ to 50 ℃ |
0.01 ℃ |
± 0.8 ℃. |
32 ℉ to 122 ℉. |
0.01 ℉ |
± 1.5 ℉. |
K/J型溫度計 (Type K/J thermometer)
Sensor type |
Resolution |
Range |
Accuracy |
Type K |
0.1 ℃ |
-50.0 to 1300.0 ℃ |
± ( 0.2 % + 0.5 ℃ ) |
-50.1 to -100.0 ℃ |
± ( 0.2 % + 1 ℃ ) |
0.1 ℉ |
-58.0 to 2372.0 ℉ |
± ( 0.2 % + 1 ℉ ) |
-58.1 to -148.0 ℉ |
± ( 0.2 % + 1.8 ℉ ) |
Type J |
0.1 ℃ |
-50.0 to 1100.0 ℃ |
± ( 0.2 % + 0.5 ℃ ) |
-50.1 to -100.0 ℃ |
± ( 0.2 % + 1 ℃ ) |
0.1 ℉ |
-58.0 to 2012.0 ℉ |
± ( 0.2 % + 1 ℉ ) |
-58.1 to -148.0 ℉ |
± ( 0.4 % + 1.8 ℉ ) |
|